Frequently Asked Questions

Q: Do I need to evacuate the building when I leak-test with EZsmoke?

                A: No.  EZsmoke’s vapor is non-toxic and even has a pleasant citrus smell.

 Q: If I’m leak-testing a water system with EZsmoke, will I need to clean any vapor residue that may be left behind?

                A: No.  EZsmoke's specially formulated and approved vapor-producing solution is a highly refined mineral oil, which is not only food-grade but is also Kosher certified.  Any residue will easily wash away.

Q: How long a run of pipe can I test with EZsmoke?

                A: Many factors have to be taken into consideration, such as pipe diameter size and if pipe size reductions are in the system.  But generally speaking, the Diagnostic Smoke® vapor will continue to travel as long as the backpressure in the system being tested does not exceed the 5 PSI delivery pressure of the EZsmoke.  So, in many cases, the smoke vapor will travel hundreds of feet.

 Q: How many tests can I get out of one bottle of oil?

                A: Approximately 50, 18-minute test cycles, from one 16 oz. bottle.  EZsmoke holds 32 oz. of solution.

 Q: What kinds of oil can I use with EZsmoke?

                A: You should only use the approved UltraTraceUV® solution.  Pleasantly scented, it is a patented non-toxic, non-contaminating solution containing a trace dye which marks the leak spots. It also easily wipes clean. Using the wrong solutions can contaminate systems under test and damage the EZsmoke unit.

 Q: What pressure limits does the EZsmoke unit have?

                A: Delivery pressure is non-adjustable and preset to 5 PSI.

 Q: What kind of pressure sources does the EZsmoke unit work with?

                A: Compressed air or any inert gas.

 Q: Can I use EZsmoke without compressed air or gas?

                A: No.

 Q: How far can I test from the EZsmoke unit?

                A: It is not uncommon for units to be used with four 25ft extensions (100 ft.).

 Q: How long does an average test take?

                A: That completely depends on the application.  But there is no method faster for finding leaks.

Q: How many people does it take to run the EZsmoke unit?

                A: One!

 Q: How long will the EZsmoke unit run a test before shutting off?

                A: It is on an 18-minute test cycle timer.

 Q: What can I test with EZsmoke?

                A: Any system not containing a liquid.

Depending on what you are looking for, the absence or presence of Diagnostic Smoke® vapor handily identifies restrictions, leaks, and flow characteristics.  With this in mind, think of the variety of test applications in your particular field of expertise.  You may be surprised at how often you will be able to rely on this helpful technology to improve your productivity.